ASTM F1697 - 09

    Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-Wound Liner Pipe Rehabilitation of Existing Sewers and Conduit

    Active Standard ASTM F1697 | Developed by Subcommittee: F17.67

    Book of Standards Volume: 08.04


      Format Pages Price  
    PDF 7 $42.00   ADD TO CART
    Hardcopy (shipping and handling) 7 $42.00   ADD TO CART
    Standard + Redline PDF Bundle 14 $50.40   ADD TO CART


    Abstract

    This specification covers the requirements and test methods for materials, dimensions, workmanship, stiffness factor, extrusion quality, and test procedures for extruded poly(vinyl chloride) (PVC) profile strips used for machine-made field fabrication of spirally wound pipe liners in the rehabilitation of a variety of existing pipelines and conduits including sanitary sewers, storm water sewers, process flow piping, and non-circular pipelines (such as arched or oval shapes and rectangular shapes) under gravity flow conditions. Certification, packaging, and product marking for quality assurance are also considered.

    This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

    Significance and Use

    The requirements of this specification are intended to provide extruded PVC profile strip suitable for the field fabrication of spirally wound liner pipe for the rehabilitation of existing pipelines and conduits conveying sewage, process flow, and storm water under gravity flow conditions.

    Note 3—Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority since chemicals not commonly found in drains and sewers and temperatures in excess of 140°F (60°C) may be encountered.

    1. Scope

    1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, stiffness factor, extrusion quality, and a form of marking for extruded poly(vinyl chloride) (PVC) profile strips used for machine made field fabrication of spirally wound pipe liners in the rehabilitation of a variety of gravity applications such as sanitary sewers, storm sewers, and process piping in diameters of 6 to 180 in. and for similar sizes of non-circular pipelines such as arched or oval shapes and rectangular shapes.

    1.2 Profile strip produced to this specification is for use in field fabrication of spirally wound liner pipes in nonpressure sewer and conduit rehabilitation, where the spirally wound liner pipe is expanded until it presses against the interior surface of the existing sewer or conduit, or, alternatively, where the spirally wound liner pipe is inserted as a fixed diameter into the existing sewer or conduit and the annular space between the liner pipe and the existing sewer or conduit is grouted.

    1.3 This specification includes extruded profile strips made only from materials specified in 5.1.

    1.4 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.

    1.5 The following precautionary caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    A167 Specification for Stainless and Heat-Resisting Chromium-Nickel Steel Plate, Sheet, and Strip

    A176 Specification for Stainless and Heat-Resisting Chromium Steel Plate, Sheet, and Strip

    A653/A653M Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

    A879/A879M Specification for Steel Sheet, Zinc Coated by the Electrolytic Process for Applications Requiring Designation of the Coating Mass on Each Surface

    A924/A924M Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process

    D618 Practice for Conditioning Plastics for Testing

    D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials

    D883 Terminology Relating to Plastics

    D1600 Terminology for Abbreviated Terms Relating to Plastics

    D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds

    D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings

    D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone Immersion

    F412 Terminology Relating to Plastic Piping Systems

    F1741 Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits

    Federal Standard

    FederalStandardNo.12 Marking for Shipment (Civil Agencies) Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://www.dodssp.daps.mil

    Military Standard

    MIL-STD-129 Marking for Shipment and Storage


    ICS Code

    ICS Number Code 23.040.20 (Plastic pipes); 83.080.20 (Thermoplastic materials)

    UNSPSC Code

    UNSPSC Code 40171518(Commercial CPVC pipe)


    DOI: 10.1520/F1697-09

    ASTM International is a member of CrossRef.