ASTM F1208-89(2005)

    Standard Specification for Minimum Performance and Safety Requirements for Anesthesia Breathing Systems (Withdrawn 2014)

    Withdrawn Standard: ASTM F1208-89(2005) | Developed by Subcommittee: F29.10

    WITHDRAWN, NO REPLACEMENT


      Format Pages Price  
    PDF 13 $58.80   ADD TO CART


    Withdrawn Rationale:

    This specification covers breathing systems and components employed with anesthesia gas machines for humans. This specification considers the circle system as a whole and some of its components individually. A particular emphasis is placed upon component arrangement in the circle absorber-type system, and submits a system of standard description and notation. Excluded are ventilators for use during anesthesia, Mapelson nonrebreathing type systems, as well as breathing systems and related components of dental analgesia machines.

    Formerly under the jurisdiction of Committee F29 on Anesthetic and Respiratory Equipment, this specification was withdrawn in July 2014 in accordance with section 10.6.3 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

    1. Scope

    1.1 This specification covers breathing systems and components employed with anesthesia gas machines for humans. This specification considers the circle system as a whole and some of its components individually. A particular emphasis is placed upon component arrangement in the circle absorber-type system, and submits a system of standard description and notation. Excluded are ventilators for use during anesthesia, Mapelson nonrebreathing type systems, as well as breathing systems and related components of dental analgesia machines. (For rationale, see Appendix X1.)

    1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    1.3 This specification is arranged as follows:

    SectionScopeReferenced DocumentsTerminologySystem ClassificationGraphic NotationsDiagramatic RulesFunctional Segments of the Circle SystemTest Procedures-GeneralSterilizationSystemsLeakage of Breathing SystemResistance of Breathing SystemsVolume of Gas Not Delivered to Patient Due to Internal ComplianceMonitoring Requirements
    Adjustable Pressure-Limiting (APL) ValvesReservoir BagsCO2 AbsorbersUnidirectional ValvesRequirementsTest ProcedureOptional ComponentsBreathing TubesFresh Gas Inlet and Fresh Gas Supply Tube or HoseConnectorsPressure GaugesY-Piece and Breathing TubesInformation in LabelingRationale



    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    F1054 Specification for Conical Fittings

    F1204 Specification for Anesthesia Reservoir Bags

    F1205 Specification for Anesthesia Breathing Tubes

    ANSI/ASME Standard

    ANSI/ASMEB40.1M-1985 Standard for Pressure Gauge Available from the American National Standards Institute, 25 W. 43rd St., 4th Floor, New York, NY 10036.


    DOI: 10.1520/F1208-89R05

    ASTM International is a member of CrossRef.

    Citation Format

    ASTM F1208-89(2005), Standard Specification for Minimum Performance and Safety Requirements for Anesthesia Breathing Systems (Withdrawn 2014), ASTM International, West Conshohocken, PA, 2005, www.astm.org