ASTM E923 - 97(2013)

    Standard Specification for Glass Westergren Tube, Reusable

    Active Standard ASTM E923 | Developed by Subcommittee: E41.01

    Book of Standards Volume: 14.04


      Format Pages Price  
    PDF 3 $37.00   ADD TO CART
    Hardcopy (shipping and handling) 3 $37.00   ADD TO CART


    Abstract

    This specification covers the design and dimensional requirements for reusable glass Westergren tubes that measure the erythrocyte sedimentation rate (ESR), which is the suspension stability, or amount of settling after a specified time, of red blood cells in diluted, anti-coagulated human blood. The tubes shall be fabricated from Type I, Class B borosilicate glass, or Type II soda lime glass. Tubes shall comply with requirements for graduation line length and numbering, marking permanency, grinding bevel, and workmanship. The tubes should also pass a pigmentation and amber stain test.

    This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

    Significance and Use

    1. Scope

    1.1 This specification describes requirements for a tube that measures the erythrocyte sedimentation rate (ESR). ESR is the suspension stability of red cells in diluted, anti-coagulated human blood.

    1.1.1 The use of the term “rate” is, strictly speaking, not correct. The test measures the amount of settling of red cells after a specified time.

    1.2 The tubes are used together with a special rack to ensure they remain in a vertical position during the test.

    1.3 This specification includes many dimensional requirements that are, for the most part, in agreement with the British Standards Institution, German Standards Institute, International Committee for Standardization in Haematology, and the National Committee for Clinical Laboratory Standards publications on Westergren tubes. The clinical procedure using the tube described in this specification is known as the “Westergren Method.”

    1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.5  This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    E438 Specification for Glasses in Laboratory Apparatus

    E920 Specification for Commercially Packaged Laboratory Apparatus

    E921 Specification for Export Packaged Laboratory Apparatus

    E1133 Practice for Performance Testing of Packaged Laboratory Apparatus for United States Government Procurements

    E1157 Specification for Sampling and Testing of Reusable Laboratory Glassware


    ICS Code

    ICS Number Code 11.100 (Laboratory medicine)

    UNSPSC Code

    UNSPSC Code


    DOI: 10.1520/E0923