Withdrawn Rationale:
These test methods cover the chemical analysis of silicomanganese and ferrosilicon manganese having chemical compositions within the following limits:
ElementConcentration, %
|
Arsenic0.10 max
Carbon3.0 max
Chromium0.50 max
Lead0.030 max
Manganese50.0 to 68.0
Molybdenum0.10 max
Nickel0.20 max
Phosphorus0.20 max
Silicon35.0 max
Sulfur0.04 max
Tin0.010 max
Formerly under the jurisdiction of Committee E01 on Analytical Chemistry for Metals, Ores, and Related Materials, these test methods were withdrawn in May 2005. This standard is being withdrawn without replacement because it does not have ILS supporting data and most laboratories are using instrumental techniques for analysis rather than the old wet chemical methods.
1. Scope
1.1 These test methods cover the chemical analysis of silicomanganese and ferrosilicon manganese having chemical compositions within the following limits:
ElementConcentration, %
|
Arsenic0.10 max
Carbon3.0 max
Chromium0.50 max
Lead0.030 max
Manganese50.0 to 68.0
Molybdenum0.10 max
Nickel0.20 max
Phosphorus0.20 max
Silicon35.0 max
Sulfur0.04 max
Tin0.010 max
1.2 The test methods in this standard are contained in the sections indicated below:
Sections
|
Arsenic by the Molybdenum Blue Photometric Method (0.002to 0.06 %)
Lead by the Dithizone Photometric Method (0.02 to 0.05 %)
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 5 and in special warning paragraphs throughout these test methods.
Keywords
chemical analysis; ferrosilicon manganese; silico-manganese;
DOI: 10.1520/E0362-99
ASTM International is a member of CrossRef.
Citing ASTM Standards