Standards

ASTM E2610 - 08(2011)


ASTM E2610 - 08(2011) Standard Test Method for Sensory Analysis—Duo-Trio Test


Active Standard ASTM E2610 Developed by Subcommittee: E18.04 |Book of Standards Volume: 15.08

more info 9 pages $ 41.00
more info 9 pages $ 41.00

Historical (view previous versions of standard) ASTM License Agreement Shipping & Handling

More E18.04 Standards Related Products
Copyright/Permissions Standard References

ASTM E2610

Significance and Use

The test method is effective for the following test objectives:

To determine whether a perceivable difference results or a perceivable difference does not result, for example, when a change is made in ingredients, processing, packaging, handling or storage; or

To select, train and monitor assessors.

The test method itself does not change whether the purpose of the duo-trio test is to determine that two products are perceivably different versus that the products are not perceivably different. Only the selected values of pd, α, and β change. If the objective of the test is to determine if there is a perceivable difference between two products, then the value selected for α is typically smaller than the value selected for β. If the objective is to determine if the two products are sufficiently similar to be used interchangeably, then the value selected for β is typically smaller than the value selected for α and the value of pd is selected to dene sufficiently similar.

The test method may change based on the test objective or the assessors familiarity with the product. The balanced-reference technique (see 9.1.1) typically is used when neither product is more familiar than the other. The constant-reference technique (see 9.1.2) frequently is used when one product is a control/current product or is familiar to the assessors.

1. Scope

1.1 This test method covers a procedure for determining whether a perceptible sensory difference exists between samples of two products.

1.2 This test method applies whether a difference may exist in a single sensory attribute or in several.

1.3 This test method is applicable when the nature of the difference between the samples is unknown. It does not determine the size or the direction of the difference. The attribute(s) responsible for the difference are not identified.

1.4 Compared to the triangle test, the duo-trio test is statistically less efficient, but easier to perform by the assessors. For details on how the duo-trio test compares to other three-sample tests, see Refs (1-4).

1.5 This test method is applicable only if the products are homogeneous. If two samples of the same product can often be distinguished, then another method, for example, descriptive analysis, may be more appropriate.

1.6 This test method is applicable only when the products do not cause excessive sensory fatigue, carryover or adaptation.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

E253 Terminology Relating to Sensory Evaluation of Materials and Products

E456 Terminology Relating to Quality and Statistics

E1871 Guide for Serving Protocol for Sensory Evaluation of Foods and Beverages

E1885 Test Method for Sensory Analysis--Triangle Test



Keywords

difference testing; discrimination test; duo-trio test; sensory analysis; similarity testing; Duo-trio test; Sensory analysis



ICS Code

ICS Number Code 67.240 (Sensory analysis)



DOI: 10.1520/E2610-08R11

ASTM International is a member of CrossRef.


Citing ASTM Standards

[Back to Top]

Standards Tracker

Standards Subscriptions


Related Standards:
E1885
E1909
E2082
E1958
E1697
See All