ASTM E2271 - 05a(2012)e1

    Standard Practice for Clearance Examinations Following Lead Hazard Reduction Activities in Dwellings, and in Other Child-Occupied Facilities

    Active Standard ASTM E2271 | Developed by Subcommittee: E06.23

    Book of Standards Volume: 04.12


    Buy Standard (PDF)
    11 pages
    $48.00
    Buy Standard (Print)
    11 pages
    $48.00

    Historical (view previous versions of standard)


    ASTM E2271

    Significance and Use

    A clearance examination of abatement areas and other areas associated with other lead-hazard control activities, or building maintenance or modification activities in single-family detached dwellings, multifamily dwellings having similar units, common areas or exterior sites, and child-occupied facilities is performed to determine that the clearance area is adequately safe for reoccupancy.

    It is the responsibility of the user of this standard to assure that all regulatory, contractual, and personnel requirements are met prior to conduct of a clearance examination. At a minimum, users of this standard shall be trained in its use and in safe practices for its conduct.

    This practice is one of a set of standards developed for lead hazard management activities. The visual assessment procedures required in this standard are found in Practice E2255 and the record keeping requirements are found in Practice E2239.

    Although this practice was primarily developed for dwellings and for other child-occupied facilities, this practice may be also applied to nonresidential buildings and related structures by agreement between the client and the individual conducting the clearance examination.

    This practice may be used by owners and property managers, including owner-occupants, and others responsible for maintaining facilities. It may also be used by lead hazard management consultants, construction contractors, labor groups, real estate and financial professionals, insurance organizations, legislators, regulators, and legal professionals.

    This standard does not address whether lead-hazard reduction activities or other building modification or maintenance work were done properly.

    1. Scope

    1.1 This practice covers visual assessment for the presence of deteriorated paint, surface dust, painted debris, and paint chips with environmental sampling of surface dust to determine whether a lead hazard exists at the time of sample collection, following lead-hazard reduction activities, or other building maintenance and modification activities.

    1.2 This practice addresses clearance examination of single-family detached dwellings (including exterior structures, such as fences), multifamily dwellings having similar units, common areas or exterior sites, and child-occupied facilities.

    1.3 This practice also addresses clearance examinations that may include soil sampling, for example when soil abatement has been performed.

    1.4 This practice includes a procedure for determining whether regulatory requirements for lead clearance levels for dust and, where warranted, soil have been met, and, consequently whether a clearance area, passes or fails a clearance examination.

    Note 1—This practice is based on that portion of clearance described in 40 CFR Part 745 for abatement, and in 24 CFR 35 for lead-hazard reduction activities other than abatement, except that composite dust sampling is not used.

    1.5 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

    1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    U.S. Regulations

    40CFR 745, Environmental Protection Agency (EPA), Lead-Based Paint Poisoning Prevention in Certain Residential Structures (especially subparts D, L and Q)

    Governmental Agency Guidance

    EPANationalLeadLabor

    ASTM Standards

    D4840 Guide for Sample Chain-of-Custody Procedures

    D5124 Practice for Testing and Use of a Random Number Generator in Lumber and Wood Products Simulation

    E631 Terminology of Building Constructions

    E1480 Terminology of Facility Management (Building-Related)

    E1605 Terminology Relating to Lead in Buildings

    E1727 Practice for Field Collection of Soil Samples for Subsequent Lead Determination

    E1728 Practice for Collection of Settled Dust Samples Using Wipe Sampling Methods for Subsequent Lead Determination

    E1792 Specification for Wipe Sampling Materials for Lead in Surface Dust

    E2239 Practice for Record Keeping and Record Preservation for Lead Hazard Activities

    E2255 Practice for Conducting Visual Assessments for Lead Hazards in Buildings


    ICS Code

    ICS Number Code 13.080.10 (Chemical characteristics of soil); 91.040.30 (Residential buildings)

    UNSPSC Code

    UNSPSC Code


    DOI: 10.1520/E2271-05AR12E01

    ASTM International is a member of CrossRef.

    ASTM E2271

    Citing ASTM Standards
    Back to Top