Withdrawn Rationale:

This guide covers considerations, criteria, principles and recommendations that should be helpful when developing, utilizing, or assessing PCR protocols to amplify and detect DNA (by PCR) or RNA [by reverse transcriptase PCR (RT-PCR)] from HIV. This guide is not a specific protocol for the detection of HIV. It is intended to provide information that will assist the user in obtaining quality and reliable data. The guide is closely related to and should be used concurrently with the general PCR guideline.

Formerly under the jurisdiction of Committee E48 on Biotechnology, this guide was withdrawn in February 2010 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.


1. Scope

1.1 This guide covers considerations, criteria, principles and recommendations that should be helpful when developing, utilizing, or assessing PCR protocols to amplify and detect DNA (by PCR) or RNA [by reverse transcriptase PCR (RT-PCR)] from HIV. This guide is not a specific protocol for the detection of HIV. It is intended to provide information that will assist the user in obtaining quality and reliable data. The guide is closely related to and should be used concurrently with the general PCR guideline E 1873.

1.2 This guide has been developed for use in any molecular biology or biotechnology laboratory. This includes but is not limited to clinical and diagnostic laboratories involved with HIV detection.

1.3 This guide does not cover details of the various methods such as gel electrophoresis, that can be utilized to identify PCR-amplified HIV nucleic acid sequences, nor does it cover details of instrument (thermocycler) calibration.

1.4 This guide does not cover specific variations of the basic PCR or RT-PCR technology (e.g., quantitative PCR, multiplex PCR and in situ PCR).

1.5 This guide does not address the additional considerations necessary for the performance and validation of a quantitative PCR test for HIV.

Note 1—Warning: Laboratory work involving certain clinical specimens and microorganisms can be hazardous to personnel.

Note 2—Precaution: Biosafety Level 2 facilities are recommended for potentially hazardous work (2), and many laboratories use Biosafety Level 3 facilities when working with HIV. Safety guidelines should be adhered to according to NCCLS M29-A and other recommendations (2).