Standards

ASTM E1982 - 98(2007)


ASTM E1982 - 98(2007) Standard Practice for Open-Path Fourier Transform Infrared (OP/FT-IR) Monitoring of Gases and Vapors in Air


Active Standard ASTM E1982 Developed by Subcommittee: E13.03 |Book of Standards Volume: 03.06

more info 17 pages $ 44.00
more info 17 pages $ 44.00

Historical (view previous versions of standard) ASTM License Agreement Shipping & Handling

ASTM E1982

Significance and Use

An OP/FT-IR monitor can, in principle, measure the concentrations of all IR-active gases and vapors in the atmosphere. Detailed descriptions of OP/FT-IR systems and the fundamental aspects of their operation are given in Guide E 1865 and the FT-IR Open-Path Monitoring Guidance Document. A method for processing OP/FT-IR data to obtain the concentrations of gases over a long, open path is given in Compendium Method TO-16. Applications of OP/FT-IR systems include monitoring for gases and vapors in ambient air, along the perimeter of an industrial facility, at hazardous waste sites and landfills, in response to accidental chemical spills or releases, and in workplace environments.

1. Scope

1.1 This practice covers procedures for using active open-path Fourier transform infrared (OP/FT-IR) monitors to measure the concentrations of gases and vapors in air. Procedures for choosing the instrumental parameters, initially operating the instrument, addressing logistical concerns, making ancillary measurements, selecting the monitoring path, acquiring data, analyzing the data, and performing quality control on the data are given. Because the logistics and data quality objectives of each OP/FT-IR monitoring program will be unique, standardized procedures for measuring the concentrations of specific gases are not explicitly set forth in this practice. Instead, general procedures that are applicable to all IR-active gases and vapors are described. These procedures can be used to develop standard operating procedures for specific OP/FT-IR monitoring applications.

1.2 This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this practice to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents

ASTM Standards
E131 Terminology Relating to Molecular Spectroscopy
E1421 Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests
E1655 Practices for Infrared Multivariate Quantitative Analysis
E168 Practices for General Techniques of Infrared Quantitative Analysis
E1685 Practice for Measuring the Change in Length of Fasteners Using the Ultrasonic Pulse-Echo Technique
Other Documents
CompendiumMethodTO-16 Long-Path Open-Path Fourier Transform Infrared Monitoring of Atmospheric Gases


Index Terms

air analysis; Fourier transform infrared; FT-IR; open-path monitoring; spectrometers ; ICS Number Code 17.180.30 (Optical measuring instruments)


DOI: 10.1520/E1982-98R07

ASTM International is a member of CrossRef.


Citing ASTM Standards

[Back to Top]

Standards Tracker

Standards Subscriptions