Significance and Use
Trace amounts of water may be detrimental to the use of chlorine in some applications. The amount of water in the chlorine must be known to prevent problems during its use.
1. Scope
1.1 This test method is designed for the on-line determination of the content of water in liquid chlorine in the concentration range of 0.5 to 15 mg/kg (ppm).
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 Review the current Material Safety Data Sheets (MSDS) for detailed information concerning toxicity, first aid procedures, and safety precautions.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 7 and Note 3.
2. Referenced Documents (purchase separately)
The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D1193 Specification for Reagent Water
E806 Test Method for Carbon Tetrachloride and Chloroform in Liquid Chlorine by Direct Injection (Gas Chromatographic Procedure)
Keywords
FTIR; IR; infrared spectrophotometry; liquid chlorine; on-line analysis; water; Chlorine/chlorine-based compounds; FTIR analysis; Infrared (IR) analysis; Infrared spectrophotometry; Liquid chemicals; Liquid chlorine; Online monitoring (in water analysis); Spectrophotometry; Water analysis;
ICS Code
ICS Number Code 71.040.50 (Physicochemical methods of analysis); 71.100.20 (Gases for industrial application)