ASTM E1774 - 12

    Standard Guide for Electromagnetic Acoustic Transducers (EMATs)

    Active Standard ASTM E1774 | Developed by Subcommittee: E07.06

    Book of Standards Volume: 03.03


    Buy Standard (PDF)
    8 pages
    $42.00
    Buy Standard (Print)
    8 pages
    $42.00
    Buy Standard + Redline (PDF)
    16 pages
    $50.40

    Historical (view previous versions of standard)


    ASTM E1774

    Significance and Use

    GeneralUltrasonic testing is a widely used nondestructive method for the examination of a material. The majority of ultrasonic examinations are performed using transducers that directly convert electrical energy into acoustic energy through the use of piezoelectric crystals. This guide describes an alternate technique in which electromagnetic energy is used to produce acoustic energy inside an electrically conductive or ferromagnetic material. EMATs have unique characteristics when compared to conventional piezoelectric ultrasonic search units, making them a significant tool for some ultrasonic examination applications.

    Specific AdvantagesSince the EMAT technique is noncontacting, it requires no fluid couplant. Important consequences of this include applications to moving objects, in remote or hazardous locations, to objects at elevated temperatures, or to objects with rough surfaces. The technique is environmentally safe since it does not use potentially polluting or hazardous chemicals. The technique facilitates the rapid scanning of components having complex geometries. EMAT signals are highly reproducible as a consequence of the manner in which the acoustic waves are generated. EMATs can produce horizontally polarized shear (SH) waves without mode conversion and can accommodate scanning while using SH waves. (Note that in order to produce this wave mode by conventional ultrasonic techniques, either an epoxy or a highly viscous couplant is required. Thus, conventional ultrasonic techniques do not lend themselves easily to scanning when using SH wave modes.) Also, EMATs provide for the capability to steer shear waves electronically.

    Specific LimitationsEMATs have very low efficiency. The insertion loss of EMATs can be as much as 40 dB or more when compared to conventional ultrasonic methods. The EMAT technique can be used only on materials that are electrical conductors or ferromagnetic. The design of EMAT probes is usually more complex than comparable piezoelectric search units. Due to their low efficiency, EMATs usually require more specialized instrumentation for the generation and detection of ultrasonic signals. High transmitting currents, low-noise receivers, and careful electrical matching is imperative in system design. In general, EMAT probes are application-specific, in the same way as piezoelectric transducers.

    1. Scope

    1.1 This guide is intended primarily for tutorial purposes. It provides an overview of the general principles governing the operation and use of electromagnetic acoustic transducers (EMATs) for ultrasonic examination.

    1.2 This guide describes a non-contact technique for coupling ultrasonic energy into an electrically conductive or ferromagnetic material, or both, through the use of electromagnetic fields. This guide describes the theory of operation and basic design considerations as well as the advantages and limitations of the technique.

    1.3 This guide is intended to serve as a general reference to assist in determining the usefulness of EMATs for a given application as well as provide fundamental information regarding their design and operation. This guide provides guidance for the generation of longitudinal, shear, Rayleigh, and Lamb wave modes using EMATs.

    1.4 This guide does not contain detailed procedures for the use of EMATs in any specific applications; nor does it promote the use of EMATs without thorough testing prior to their use for examination purposes. Some applications in which EMATs have been applied successfully are outlined in Section 9.

    1.5 UnitsThe value stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

    1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    Aerospace Industries Association Standard

    NAS-410 Certification and Qualification of Nondestructive Test Personnel Available from Aerospace Industries Association of America, Inc. (AIA), 1000 Wilson Blvd., Suite 1700, Arlington, VA 22209-3928, http://www.aia-aerospace.org.

    ASTM Standards

    E127 Practice for Fabricating and Checking Aluminum Alloy Ultrasonic Standard Reference Blocks

    E428 Practice for Fabrication and Control of Metal, Other than Aluminum, Reference Blocks Used in Ultrasonic Testing

    E543 Specification for Agencies Performing Nondestructive Testing

    E1065 Guide for Evaluating Characteristics of Ultrasonic Search Units

    E1316 Terminology for Nondestructive Examinations


    ICS Code

    ICS Number Code 17.140.01 (Acoustic measurements and noise abatement in general)

    UNSPSC Code

    UNSPSC Code 41111804(Ultrasonic examination equipment)


    DOI: 10.1520/E1774-12

    ASTM International is a member of CrossRef.

    ASTM E1774

    Citing ASTM Standards
    Back to Top