ASTM E1514 - 98(2011)

    Standard Specification for Structural Standing Seam Steel Roof Panel Systems

    Active Standard ASTM E1514 | Developed by Subcommittee: E06.57

    Book of Standards Volume: 04.11


      Format Pages Price  
    PDF 5 $43.00   ADD TO CART
    Hardcopy (shipping and handling) 5 $43.00   ADD TO CART


    Abstract

    This specification covers the design, construction, and weatherability of structural standing seam steel roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers. Panel material shall be a hot dip metallic coated product in accordance with one of the following commonly used materials: aluminum-, aluminum-zinc alloy-, zinc-, or zinc-5% aluminum alloy metallic-coated sheet steel. The roof system shall be designed for specified design loads and thermal effects without causing seam separation, permanent panel buckling, or weather-tightness loss. Deflection and serviceability shall be accounted for in the panel system for structural integrity. Static and uplift index tests shall be performed to determine the roof's load capacity. Standing seam roof panel systems shall be installed in accordance with the system design requirements.

    This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

    1. Scope

    1.1 This specification covers the design, construction, and weatherability of structural standing seam steel roof panel systems. It includes performance requirements for the following elements only: panels, concealed panel clips, panel/clip anchorage, and panel joint sealers.

    Note 1—These systems are used on both low-slope and steep-slope roof applications. They also are used with or without an underlying deck or sheathing.

    1.2 The objective of this specification is to provide for the overall performance of the structural standing seam steel roof panel system as defined in 3.2.6 during its service life in order to provide weather protection, carry the specified design loads, and allow proper access over the roof surface in order to provide for periodic maintenance of equipment by the owner.

    1.3 In addition to structural, the specifier shall evaluate other characteristics beyond the scope of this specification that affect the final choice of roof construction. These include, but are not limited to, functional, legal, insurance, and economic considerations. See Appendix X1 for specifier's checklist.

    1.4 The specification is not intended to exclude products or systems not covered by the referenced documents.

    1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

    1.6 The text of this specification contains notes and footnotes that provide explanatory information and are not requirements of this specification.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    AISI Document

    S100 North American Specification for the Design of Cold-Formed Steel Structure Members

    MBMA Document

    MBMA Low Rise Building Systems Manual, Latest Edition

    ASTM Standards

    A463/A463M Specification for Steel Sheet, Aluminum-Coated, by the Hot-Dip Process

    A653/A653M Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process

    A792/A792M Specification for Steel Sheet, 55 % Aluminum-Zinc Alloy-Coated by the Hot-Dip Process

    A875/A875M Specification for Steel Sheet, Zinc-5 % Aluminum Alloy-Coated by the Hot-Dip Process

    C711 Test Method for Low-Temperature Flexibility and Tenacity of One-Part, Elastomeric, Solvent-Release Type Sealants

    C765 Test Method for Low-Temperature Flexibility of Preformed Tape Sealants

    C879 Test Methods for Release Papers Used with Preformed Tape Sealants

    D1667 Specification for Flexible Cellular Materials--Poly (Vinyl Chloride) Foam (Closed-Cell)

    D3310 Test Method for Determining Corrosivity of Adhesive Materials

    E631 Terminology of Building Constructions

    E1592 Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference

    E1646 Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference

    E1680 Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems

    G21 Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi

    FM Approvals LLC Standard

    ApprovalStandard for Class 1 Panel Roofs, Class Number 4471


    ICS Code

    ICS Number Code 91.060.20 (Roofs)