ASTM D7418 - 12

    Standard Practice for Set-Up and Operation of Fourier Transform Infrared (FT-IR) Spectrometers for In-Service Oil Condition Monitoring

    Active Standard ASTM D7418 | Developed by Subcommittee: D02.96

    Book of Standards Volume: 05.04


      Format Pages Price  
    PDF 10 $43.00   ADD TO CART
    Hardcopy (shipping and handling) 10 $43.00   ADD TO CART
    Standard + Redline PDF Bundle 20 $51.60   ADD TO CART


    Significance and Use

    4.1 This practice describes to the end user how to collect the FT-IR spectra of in-service oil samples for in-service oil condition monitoring. Various in-service oil condition monitoring parameters, such as oxidation, nitration, soot, water, ethylene glycol, fuel dilution, gasoline dilution, sulfate by-products and phosphate antiwear additives, can be measured by FT-IR spectroscopy (5-8), as described in Practice E2412. Changes in the values of these parameters over operating time can then be used to help diagnose the operational condition of various machinery and equipment and to indicate when an oil change should take place. This practice is intended to give a standardized configuration for FT-IR instrumentation and operating parameters employed in in-service oil condition monitoring in order to obtain comparable between-instrument and between-laboratory data.

    1. Scope

    1.1 This practice covers the instrument set-up and operation parameters for using FT-IR spectrometers for in-service oil condition monitoring for both direct trend analysis and differential trend analysis approaches.

    1.2 This practice describes how to acquire the FT-IR spectrum of an in-service oil sample using a standard transmission cell and establishes maximum allowable spectral noise levels.

    1.3 Measurement and integrated parameters for individual in-service oil condition monitoring components and parameters are not described in this practice and are described in their respective test methods.

    1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

    1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    D4057 Practice for Manual Sampling of Petroleum and Petroleum Products

    E131 Terminology Relating to Molecular Spectroscopy

    E168 Practices for General Techniques of Infrared Quantitative Analysis

    E1421 Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests

    E1866 Guide for Establishing Spectrophotometer Performance Tests

    E2412 Practice for Condition Monitoring of In-Service Lubricants by Trend Analysis Using Fourier Transform Infrared (FT-IR) Spectrometry


    ICS Code

    ICS Number Code 75.160.20 (Liquid fuels)

    UNSPSC Code

    UNSPSC Code 41115408(Infrared spectrometers)


    Referencing This Standard

    DOI: 10.1520/D7418-12

    ASTM International is a member of CrossRef.

    Citation Format

    ASTM D7418-12, Standard Practice for Set-Up and Operation of Fourier Transform Infrared (FT-IR) Spectrometers for In-Service Oil Condition Monitoring, ASTM International, West Conshohocken, PA, 2012, www.astm.org