Significance and Use
5.1 This test method provides a means of evaluating roof membranes, seams, and laps for resistance to water migration from standing water on the roof. This test method evaluates roof membranes when first applied and also after simulated deterioration caused by the ultraviolet energy of the sun.
1. Scope
1.1 This test method covers the determination of water migration resistance of roof membranes including built-up roof membranes, modified bitumen, and single ply roof membranes. The procedures were developed to determine the potential for leakage of water through the roof membranes resulting from a standing head of water and when pressurized with air from the underside.
1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately)
The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
G154 Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials
Keywords
condensation; laminated; roof membrane; ultraviolet radiation; water leakage; weathering;
ICS Code
ICS Number Code 91.100.50 (Binders. Sealing materials)
DOI: 10.1520/D7281
ASTM International is a member of CrossRef.