ASTM D5475-93(2002)

    Withdrawn Standard: ASTM D5475-93(2002) Standard Test Method for Nitrogen- and Phosphorus-Containing Pesticides in Water by Gas Chromatography with a Nitrogen-Phosphorus Detector (Withdrawn 2011)

    Developed by Subcommittee: D19.06

    WITHDRAWN, NO REPLACEMENT

    Buy Standard (PDF)
    15 pages
    $57.60


    Withdrawn Rationale:

    Formerly under the jurisdiction of Committee D19 on Water, this Test Method was withdrawn in 2011 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

    1. Scope

    1.1 This is a gas chromatographic (GC) test method applicable to the determination of certain nitrogen- and phosphorus-containing pesticides in ground water and finished drinking water. The analytes listed in have been validated using this test method.

    1.2 This test method has been validated on reagent water and finished drinking water by 10 volunteer laboratories. Summary statistics were calculated for mean recovery, overall method precision and bias and single analyst precision using a computer program, Interlaboratory Method Validation Study (IMVS).

    1.3 Collaborative study showed the test method to be acceptable for all analytes tested except merphos, which decomposed in the GC injection port.

    1.4 This test method is restricted to use by or under the supervision of analysts experienced in the use of GC and in the interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results with this test method using the procedure described in 12.3.

    1.5 Analytes that are not separated chromatographically, that is, analytes which have very similar retention times, cannot be individually identified and measured in the same calibration mixture or water sample unless an alternative technique for identification and quantitation exist (13.5).

    1.6 When this test method is used to analyze unfamiliar samples for any or all of the analytes above, analyte identifications should be confirmed by at least one additional qualitative technique.

    1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    D1129 Terminology Relating to Water

    D1192 Specification for Equipment for Sampling Water and Steam in Closed Conduits

    D1193 Specification of Reagent Water

    D2777 Practice for Determination of Precision and Bias of Applicable Methods of Committee D19 on Water

    D3370 Practices for Sampling Water from Closed Conduits

    D3694 Practices for Preparation of Sample Containers and for Preservation of Organic Constituents

    U.S. EPA Method

    EPAMethod507, Revision 2.0 Determination of Nitrogen- and Phosphorus-Containing Pesticides in Water by Gas Chromatography with a Nitrogen-Phosphorus Detector


    DOI: 10.1520/D5475-93R02

    ASTM International is a member of CrossRef.


    Citing ASTM Standards
    Back to Top