Standards

ASTM D5270 - 96(2008)


ASTM D5270 - 96(2008) Standard Test Method for Determining Transmissivity and Storage Coefficient of Bounded, Nonleaky, Confined Aquifers


Active Standard ASTM D5270 Developed by Subcommittee: D18.21 |Book of Standards Volume: 04.08

more info 7 pages $ 41.00
more info 7 pages $ 41.00

Historical (view previous versions of standard) ASTM License Agreement Shipping & Handling

More D18.21 Standards Related Products
Copyright/Permissions Standard References

ASTM D5270

Significance and Use

Assumptions:

The well discharges at a constant rate.

Well is of infinitesimal diameter and is open through the full thickness of the aquifer.

The nonleaky confined aquifer is homogeneous, isotropic, and areally extensive except where limited by linear boundaries.

Discharge from the well is derived initially from storage in the aquifer; later, movement of water may be induced from a constant-head boundary into the aquifer.

The geometry of the assumed aquifer and well are shown in Fig. 1 or Fig. 2.

Boundaries are vertical planes, infinite in length that fully penetrate the aquifer. No water is yielded to the aquifer by impermeable boundaries, whereas recharging boundaries are in perfect hydraulic connection with the aquifer.

Observation wells represent the head in the aquifer; that is, the effects of wellbore storage in the observation wells are negligible.

Implications of Assumptions:

Implicit in the assumptions are the conditions of a fully-penetrating control well and observation wells of infinitesimal diameter in a confined aquifer. Under certain conditions, aquifer tests can be successfully analyzed when the control well is open to only part of the aquifer or contains a significant volume of water or when the test is conducted in an unconfined aquifer. These conditions are discussed in more detail in Test Method D4105.

In cases in which this test method is used to locate an unknown boundary, a minimum of three observation wells is needed. If only two observation wells are available, two possible locations of the boundary are defined, and if only one observation well is used, a circle describing all possible locations of the image well is defined.

The effects of a constant-head boundary are often indistinguishable from the effects of a leaky, confined aquifer. Therefore, care must be taken to ensure that a correct conceptual model of the system has been created prior to analyzing the test. See Guide D4043.

1. Scope

1.1 This test method covers an analytical procedure for determining the transmissivity, storage coefficient, and possible location of boundaries for a confined aquifer with a linear boundary. This test method is used to analyze water-level or head data from one or more observation wells or piezometers during the pumping of water from a control well at a constant rate. This test method also applies to flowing artesian wells discharging at a constant rate. With appropriate changes in sign, this test method also can be used to analyze the effects of injecting water into a control well at a constant rate.

1.2 The analytical procedure in this test method is used in conjunction with the field procedure in Test Method D4050.

1.3 LimitationsThe valid use of this test method is limited to determination of transmissivities and storage coefficients for aquifers in hydrogeologic settings with reasonable correspondence to the assumptions of the Theis nonequilibrium method (see Test Method D4106) (see 5.1), except that the aquifer is limited in areal extent by a linear boundary that fully penetrates the aquifer. The boundary is assumed to be either a constant-head boundary (equivalent to a stream or lake that hydraulically fully penetrates the aquifer) or a no-flow (impermeable) boundary (equivalent to a contact with a significantly less permeable rock unit). The Theis nonequilibrium method is described in Test Methods D4105 and D4106.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

ASTM Standards

D653 Terminology Relating to Soil, Rock, and Contained Fluids

D4043 Guide for Selection of Aquifer Test Method in Determining Hydraulic Properties by Well Techniques

D4050 Test Method for (Field Procedure) for Withdrawal and Injection Well Tests for Determining Hydraulic Properties of Aquifer Systems

D4105 Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Modified Theis Nonequilibrium Method

D4106 Test Method for (Analytical Procedure) for Determining Transmissivity and Storage Coefficient of Nonleaky Confined Aquifers by the Theis Nonequilibrium Method

D4750 Test Method for Determining Subsurface Liquid Levels in a Borehole or Monitoring Well (Observation Well)



Keywords

aquifer boundaries; aquifer tests; aquifers; confined aquifers; control wells; ground water; hydraulic properties; image wells; observation wells; storage coefficient; transmissivity; Aquifers; Boundary conditions; Confined aquifers; Control wells; Draw-down test; Field testing--ground water/aquifers; Ground water; Hydraulic conductivity/transmissivity; Observation wells; Storativity; Transmissivity;



ICS Code

ICS Number Code 13.060.10 (Water of natural resources)



DOI: 10.1520/D5270-96R08

ASTM International is a member of CrossRef.


Citing ASTM Standards

[Back to Top]

Standards Tracker

Standards Subscriptions


Related Standards:
D6029
D6028
D4106
D4105
D5855
See All