ASTM D5011 - 92(2009)

    Standard Practices for Calibration of Ozone Monitors Using Transfer Standards

    Active Standard ASTM D5011 | Developed by Subcommittee: D22.03

    Book of Standards Volume: 11.07


    Buy Standard (PDF)
    28 pages
    $60.00
    Buy Standard (Print)
    28 pages
    $60.00

    Historical (view previous versions of standard)


    ASTM D5011

    Significance and Use

    The reactivity and instability of O3 precludes the storage of O3 concentration standards for any practical length of time, and precludes direct certification of O3 concentrations as SRM's. Moreover, there is no available SRM that can be readily and directly adapted to the generation of O3 standards analogous to permeation devices and standard gas cylinders for sulfur dioxide and nitrogen oxides. Dynamic generation of O3 concentrations is relatively easy with a source of ultraviolet (UV) radiation. However, accurately certifying an O3 concentration as a primary standard requires assay of the concentration by a comprehensively specified analytical procedure, which must be performed every time a standard is needed.

    The primary UV standard photometers, which are usually used at a fixed location under controlled conditions, are used to certify transfer standards that are then transported to the field sites where the ambient ozone monitors are being used. See Practice D 5110.

    The advantages of this procedure are:

    All O3 monitors in a given network or region may be traced to a single primary standard.

    The primary standard is used at only one location, under controlled conditions.

    Transfer standards are more rugged and more easily portable than primary standards.

    Transfer standards may be used to intercompare various primary standards.

    1. Scope

    1.1 These practices describe means for calibrating ambient, workplace or indoor ozone monitors, using transfer standards.

    1.2 These practices describe five types of transfer standards:

    (A) Analytical instruments

    (B) Boric acid potassium iodide (BAKI) manual analytical procedure

    (C) Gas phase titration with excess nitric oxide

    (D) Gas phase titration with excess ozone

    (E) Ozone generator device.

    1.3 These practices describe procedures to establish the authority of transfer standards: qualification, certification, and periodic recertification.

    1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 8 for specific precautionary statements.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    D1071 Test Methods for Volumetric Measurement of Gaseous Fuel Samples

    D1193 Specification for Reagent Water

    D1356 Terminology Relating to Sampling and Analysis of Atmospheres

    D3195 Practice for Rotameter Calibration

    D3249 Practice for General Ambient Air Analyzer Procedures

    D3631 Test Methods for Measuring Surface Atmospheric Pressure

    D5110 Practice for Calibration of Ozone Monitors and Certification of Ozone Transfer Standards Using Ultraviolet Photometry

    E591 Practice for Safety and Health Requirements Relating to Occupational Exposure to Ozone


    ICS Code

    ICS Number Code 13.040.01 (Air quality in general)

    UNSPSC Code

    UNSPSC Code 77121501(Air quality management)


    DOI: 10.1520/D5011-92R09

    ASTM International is a member of CrossRef.

    ASTM D5011

    Citing ASTM Standards
    Back to Top