ASTM D4597 - 10

    Standard Practice for Sampling Workplace Atmospheres to Collect Gases or Vapors with Solid Sorbent Diffusive Samplers

    Active Standard ASTM D4597 | Developed by Subcommittee: D22.04

    Book of Standards Volume: 11.07


    Buy Standard (PDF)
    4 pages
    $37.00
    Buy Standard (Print)
    4 pages
    $37.00
    Buy Standard + Redline (PDF)
    8 pages
    $44.40

    Historical (view previous versions of standard)


    ASTM D4597

    Significance and Use

    Regulations such as those promulgated by the U.S. Occupational Safety and Health Administration in 29 CFR 1910.1000 designate that certain hazardous gases and vapors must not be present in the workplace air at concentrations above specific values.

    This practice, when used in conjunction with an analytical technique, such as that given for organic compounds in Practice D3687, may provide a means for the determination of time-weighted airborne concentrations of many of the hazardous gases and vapors in applicable regulations (for example, 29CFR 1919.1000,), as well as others.

    The manufacturer's literature should be consulted for the appropriate list of chemicals which may be sampled by a particular device.

    1. Scope

    1.1 This practice covers the sampling of workplace atmospheres for the presence of certain gases or vapors by means of diffusion across a specified quiescent region and subsequent sorption on a solid sorbent (1).

    1.2 A list of organic compounds which are applicable to solid sorbent sampling where the sorbent is contained in a bed through which air is passed is given in Annex A1 of Practice D3686. Diffusive samplers may be applicable to a similar range of compounds but this must be confirmed by reference to the individual sampler manufacturers' literature.

    1.3 The valid use of diffusive samplers depends on the existence of actual laboratory or field validation, or both. Guidance on validation can be obtained from published protocols (2-6). This practice is not designed to cover the verification, validation, or specific test procedures used to assess the accuracy or precision of diffusive samplers.

    1.4 The values stated in SI units shall be regarded as the standard.

    1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    D1356 Terminology Relating to Sampling and Analysis of Atmospheres

    D3686 Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)

    D3687 Practice for Analysis of Organic Compound Vapors Collected by the Activated Charcoal Tube Adsorption Method

    D6306 Guide for Placement and Use of Diffusion Controlled Passive Monitors for Gaseous Pollutants in Indoor Air

    Other Document

    Title29CFR 1910.1000 Subpart Z Occupational Health and Safety Standard


    ICS Code

    ICS Number Code 13.040.30 (Workplace atmospheres); 13.100 (Occupational safety. Industrial hygiene)

    UNSPSC Code

    UNSPSC Code 93141808(Occupational health or safety services); 77121501(Air quality management)


    DOI: 10.1520/D4597-10

    ASTM International is a member of CrossRef.

    ASTM D4597

    Citing ASTM Standards
    Back to Top