ASTM D2702 - 05(2011)

    Standard Practice for Rubber Chemicals—Determination of Infrared Absorption Characteristics

    Active Standard ASTM D2702 | Developed by Subcommittee: D11.11

    Book of Standards Volume: 09.01


      Format Pages Price  
    PDF 4 $37.00   ADD TO CART
    Hardcopy (shipping and handling) 4 $37.00   ADD TO CART


    Significance and Use

    This procedure can be used for a variety of applications, including identifying unlabeled material, process control, raw material acceptance, product evaluation, and compositional change during environmental testing.

    Rubber chemicals vary widely in their chemical and physical properties. Infrared spectrophotometers vary in the presentation of a spectrum (some are linear with absorbance, others with transmittance, some use grating for energy dispersion, others use a sodium chloride prism, some obtain a spectrum through a mathematical Fourier Transform, and the like). For these reasons, a single universal method of specimen preparation and set of instrument parameters is not possible.

    By using a specific sampling procedure and operating conditions, a given spectrophotometer will give an absorption curve that is characteristic of the rubber chemical or mixture under investigation.

    The ability to superimpose the infrared spectrum of the test specimen upon that of a reference specimen, obtained under the same conditions, is evidence that the two are identical.

    The presence of additional absorption bands in either the test specimen or the reference specimen indicates the presence of one or more additional components.

    1. Scope

    1.1 This practice covers a simple, rapid practice to prove the identity of a rubber chemical before incorporation into a rubber mix by comparison of its infrared absorption spectrum with that of a reference specimen.

    1.2 This technique can also be used to detect gross contamination or large differences in rubber chemicals. Thus, it can provide a basis for producer-consumer agreement.

    1.3 Wherever infrared spectrophotometer is used, Fourier Transform Infrared Spectrometer (FTIR) may also be understood.

    1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    E131 Terminology Relating to Molecular Spectroscopy

    E168 Practices for General Techniques of Infrared Quantitative Analysis

    E275 Practice for Describing and Measuring Performance of Ultraviolet and Visible Spectrophotometers


    ICS Code

    ICS Number Code 83.040.10 (Latex and raw rubber)

    UNSPSC Code

    UNSPSC Code


    DOI: 10.1520/D2702-05R11