ASTM D2464 - 13

    Standard Specification for Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80

    Active Standard ASTM D2464 | Developed by Subcommittee: F17.10

    Book of Standards Volume: 08.04


      Format Pages Price  
    PDF 5 $43.00   ADD TO CART
    Hardcopy (shipping and handling) 5 $43.00   ADD TO CART
    Standard + Redline PDF Bundle 10 $51.60   ADD TO CART


    Abstract

    This specification covers poly(vinyl chloride) (PVC) threaded Schedule 80 pipe fittings, which are PVC 12454, 12454, 13354, 11443, and 14333. The pipe fittings are intended for use with the distribution of pressurized liquids only, which are chemically compatible with the piping materials. The materials shall conform to the required dimensions and burst pressure limits.

    This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

    1. Scope

    1.1 This specification covers poly(vinyl chloride) (PVC) threaded Schedule 80 pipe fittings. Included are requirements for materials, workmanship, dimensions, and burst pressure.

    Note 1Threaded CPVC plastic pipe fittings, Schedule 80, which were formerly included in this standard, are now covered by Specification F437.

    1.2 The products covered by this specification are intended for use with the distribution of pressurized liquids only, which are chemically compatible with the piping materials. Due to inherent hazards associated with testing components and systems with compressed air or other compressed gases some manufacturers do not allow pneumatic testing of their products. Consult with specific product/component manufacturers for their specific testing procedures prior to pneumatic testing.

    Note 2Pressurized (compressed) air or other compressed gases contain large amounts of stored energy which present serious safety hazards should a system fail for any reason.

    1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.

    1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.

    1.5 The following safety hazards caveat pertains only to the test method portion, Section 7, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    D618 Practice for Conditioning Plastics for Testing

    D1599 Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

    D1600 Terminology for Abbreviated Terms Relating to Plastics

    D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds

    D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings

    D2749 Symbols for Dimensions of Plastic Pipe Fittings

    F412 Terminology Relating to Plastic Piping Systems

    F437 Specification for Threaded Chlorinated Poly(Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80

    F1498 Specification for Taper Pipe Threads 60 for Thermoplastic Pipe and Fittings

    NSF Standard

    StandardNo.14 for Plastic Piping Components and Related Materials Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd., Ann Arbor, MI 48113-0140, http://www.nsf.org.

    StandardNo.61 for Drinking Water Systems Components--Health Effects

    Federal Standard

    Fed.Std.No.123 Marking for Shipment (Civil Agencies) Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http://dodssp.daps.dla.mil.

    Military Standard

    MIL-STD-129 Marking for Shipment and Storage


    ICS Code

    ICS Number Code 83.080.20 (Thermoplastic materials)

    UNSPSC Code

    UNSPSC Code 40170000(Pipe piping and pipe fittings)


    Referencing This Standard

    DOI: 10.1520/D2464-13

    ASTM International is a member of CrossRef.

    Citation Format

    ASTM D2464-13, Standard Specification for Threaded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80, ASTM International, West Conshohocken, PA, 2013, www.astm.org