ASTM D1253 - 14

    Standard Test Method for Residual Chlorine in Water

    Active Standard ASTM D1253 | Developed by Subcommittee: D19.05

    Book of Standards Volume: 11.01


      Format Pages Price  
    PDF 6 $43.00   ADD TO CART
    Hardcopy (shipping and handling) 6 $43.00   ADD TO CART
    Standard + Redline PDF Bundle 12 $51.60   ADD TO CART


    Significance and Use

    5.1 Chlorine is used to destroy or deactivate a variety of unwanted chemicals and microorganisms in water and wastewater.

    5.2 An uncontrolled excess of chlorine in water, whether free available or combined, can adversely affect the subsequent use of the water.

    1. Scope

    1.1 This test method covers the determination of residual chlorine in water by direct amperometric titration.

    1.2 Within the constraints specified in Section 6, this test method is not subject to commonly encountered interferences and is applicable to most waters. Some waters, however, can exert an iodine demand, usually because of organic material, making less iodine available for measurement by this test method. Thus, it is possible to obtain falsely low chlorine readings, even though the test method is working properly, without the user's knowledge.

    1.3 Precision data for this test method were obtained on estuary, inland main stem river, fresh lake, open ocean, and fresh cooling tower blowdown water. Bias data could not be determined because of the instability of solutions of chlorine in water. It is the user's responsibility to ensure the validity of the test method for untested types of water.

    1.4 In the testing by which this standard was validated, the direct and back starch-iodide titrations and the amperometric back titration, formerly part of this standard, were found to be unworkable and were discontinued in 1986. Historical information is presented in Appendix X1.

    Note 1Orthotolidine test methods have been omitted because of poor precision and accuracy.

    1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    D1129 Terminology Relating to Water

    D1193 Specification for Reagent Water

    D2777 Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water

    D3370 Practices for Sampling Water from Closed Conduits

    D5847 Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis


    ICS Code

    ICS Number Code 13.060.50 (Examination of water for chemical substances)

    UNSPSC Code

    UNSPSC Code


    Referencing This Standard

    DOI: 10.1520/D1253

    ASTM International is a member of CrossRef.

    Citation Format

    ASTM D1253-14, Standard Test Method for Residual Chlorine in Water, ASTM International, West Conshohocken, PA, 2014, www.astm.org