ASTM C412M - 11

    Standard Specification for Concrete Drain Tile (Metric)

    Active Standard ASTM C412M | Developed by Subcommittee: C13.01

    Book of Standards Volume: 04.05


      Format Pages Price  
    PDF 6 $42.00   ADD TO CART
    Hardcopy (shipping and handling) 6 $42.00   ADD TO CART
    Standard + Redline PDF Bundle 12 $50.40   ADD TO CART


    Abstract

    This specification covers concrete drain tile, to be used for surface and subsurface drainage. Manufactured drain tile shall be of the following classes: standard-quality concrete drain tile, extra-quality concrete drain tile, heavy-duty extra-quality concrete drain tile, and special-quality concrete drain tile. The concrete shall consist of mineral aggregates, water, and cementitious materials that include Portland cement, fly ash, ground granulated blast furnace slag, aggregates, admixtures and blends, and synthetic fibers. Concrete drain tile shall meet the physical requirement of the specification according to class, depending on soil acidity and sulfate content. Test specimens shall meet the external load crushing strength test requirement of the specification.

    This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

    Significance and Use

    1. Scope

    1.1 This specification covers concrete drain tile with internal diameters from 100 to 900 mm, that are intended to be used for surface and subsurface drainage.

    1.2 This specification is the metric counterpart of Specification C412.

    Note 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    C33 Specification for Concrete Aggregates

    C150 Specification for Portland Cement

    C497M Test Methods for Concrete Pipe, Manhole Sections, or Tile [Metric]

    C595 Specification for Blended Hydraulic Cements

    C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete

    C822 Terminology Relating to Concrete Pipe and Related Products

    C989 Specification for Slag Cement for Use in Concrete and Mortars

    C1116 Specification for Fiber-Reinforced Concrete and Shotcrete


    UNSPSC Code

    UNSPSC Code 70171800(Drainage services)


    DOI: 10.1520/C0412M-11

    ASTM International is a member of CrossRef.

    ASTM C412M

    Citing ASTM Standards
    Back to Top