ASTM C412 - 11

    Standard Specification for Concrete Drain Tile

    Active Standard ASTM C412 | Developed by Subcommittee: C13.01

    Book of Standards Volume: 04.05


      Format Pages Price  
    PDF 6 $43.00   ADD TO CART
    Hardcopy (shipping and handling) 6 $43.00   ADD TO CART
    Standard + Redline PDF Bundle 12 $51.60   ADD TO CART


    Abstract

    This specification covers concrete drain tile, of specific internal diameters, intended for surface and subsurface drainage. The concrete shall consist of cementitious materials, mineral aggregates, and water. The cementitious materials could be cement, fly ash, ground granulated blast surface slag, or a combination of the said materials. The physical test requirements for standard-quality tile, extra-quality tile, heavy-duty extra-quality tile, and special-quality tile are detailed in the specification. The tile shall be subjected to an external load crushing strength test and an absorption test.

    This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

    1. Scope

    1.1 This specification covers concrete drain tile with internal diameters from 4 to 36 in. that are intended to be used for surface and subsurface drainage.

    1.2 A complete metric companion to Specification C412 has been developedC412M; therefore, no metric equivalents are presented in this specification.

    Note 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    C33 Specification for Concrete Aggregates

    C150 Specification for Portland Cement

    C497 Test Methods for Concrete Pipe, Manhole Sections, or Tile

    C595 Specification for Blended Hydraulic Cements

    C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete

    C822 Terminology Relating to Concrete Pipe and Related Products

    C989 Specification for Slag Cement for Use in Concrete and Mortars

    C1116 Specification for Fiber-Reinforced Concrete and Shotcrete


    UNSPSC Code

    UNSPSC Code 30131703(Concrete tiles or flagstones)


    DOI: 10.1520/C0412-11

    ASTM International is a member of CrossRef.

    ASTM C412

    Citing ASTM Standards
    Back to Top