Abstract
This specification covers concrete drain tile, of specific internal diameters, intended for surface and subsurface drainage. The concrete shall consist of cementitious materials, mineral aggregates, and water. The cementitious materials could be cement, fly ash, ground granulated blast surface slag, or a combination of the said materials. The physical test requirements for standard-quality tile, extra-quality tile, heavy-duty extra-quality tile, and special-quality tile are detailed in the specification. The tile shall be subjected to an external load crushing strength test and an absorption test.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers concrete drain tile with internal diameters from 4 to 36 in. that are intended to be used for surface and subsurface drainage.
1.2 A complete metric companion to Specification C 412 has been developed—C 412M; therefore, no metric equivalents are presented in this specification.
Note 1—This specification is a manufacturing and purchase specification only and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of drain tile. However, experience has shown that the successful performance of the product depends upon the proper selection of the class of drain tile, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner is cautioned that he must correlate the field requirements with the class of drain tile specified and provide for or require inspection at the construction site.
2. Referenced Documents
C1116 Specification for Fiber-Reinforced Concrete and Shotcrete
C150 Specification for Portland Cement
C497 Test Methods for Concrete Pipe, Manhole Sections, or Tile
C595 Specification for Blended Hydraulic Cements
C618 Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete
C822 Terminology Relating to Concrete Pipe and Related Products
C989 Specification for Ground Granulated Blast-Furnace Slag for Use in Concrete and Mortars
Index Terms
concrete drain tile; subsurface drainage; surface drainage; tile
DOI: 10.1520/C0412-05A

ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]