ASTM C1743 - 12

    Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential Building Construction

    Active Standard ASTM C1743 | Developed by Subcommittee: C16.21

    Book of Standards Volume: 04.06


      Format Pages Price  
    PDF 6 $43.00   ADD TO CART
    Hardcopy (shipping and handling) 6 $43.00   ADD TO CART
    Standard + Redline PDF Bundle 12 $51.60   ADD TO CART


    Significance and Use

    In this practice it is recognized that effectiveness, safety, and durability of an RBS depends not only on the quality of the materials, but also on proper installation.

    Improper installation of an RBS will reduce the thermal effectiveness, cause fire risks and other unsafe conditions, and promote deterioration of the structure in which it is installed. Improper installations include fires caused by: (1) heat buildup in recessed lighting fixtures, (2) deterioration or failure of electrical wiring components, and (3) deterioration in wood structures and paint failure as a result of moisture accumulation.

    This practice provides directions for the installation of RBS products in a safe and effective manner. Actual conditions in existing buildings vary greatly and care shall be taken to ensure safe and effective installation.

    In this practice requirements are presented that are both general and specific in nature and practical. They are not intended as specific instructions unless so indicated. The user shall consult the manufacturer for recommended application and installation methods. The requirements in this practice shall be the minimum material and installation requirements for RBS.

    1. Scope

    1.1 This practice has been prepared for use by the designer, specifier, builder, and the installer of radiant barrier systems (RBS) for use in (multi- and single-family) residential building construction, not otherwise restricted from use. The scope is limited to instructions relative to the use and installation of RBS, including a surface(s) normally having an emittance of 0.1 or less, such as metallic foil or metallic foil deposits, mounted on substrates. Some examples that this practice is intended to address include: (1) low-emittance surfaces in vented building envelope cavities intended to retard radiant transfer across the airspace: (2) low-emittance surfaces at interior building surfaces intended to retard radiant transfer to, or from, building inhabitants; and (3) low-emittance surface at interior building surfaces intended to reduce radiant transfer to, or from, radiant heating or cooling systems.

    1.2 This practice covers the installation process from pre-installation inspection through the post-installation procedure. It does not cover the production of the radiant barrier materials. (See Specification C1313.)

    1.3 This practice is not intended to replace the manufacturers installation instructions but shall be used in conjunction with such instructions. This practice is not intended to supercede local, state, federal, or international codes.

    1.4 This practice assumes that the installer possesses a good working knowledge of the applicable codes and regulations, safety practices, tools, equipment, and methods necessary for installation of radiant barrier materials. It also assumes that the installer understands the fundamentals of residential building construction that affect the installation of RBS.

    1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

    1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements see Sections 5 and 7.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    C168 Terminology Relating to Thermal Insulation

    C1313 Specification for Sheet Radiant Barriers for Building Construction Applications

    NFPA Standards

    Other Document

    CPSC Product Safety Fact Sheet No. 18 The Home Electrical System


    ICS Code

    ICS Number Code 91.120.99 (Other standards related to protection of and in buildings)

    UNSPSC Code

    UNSPSC Code 30000000(Structures and Building and Construction and Manufacturing Components and Supplies)


    Referencing This Standard

    DOI: 10.1520/C1743-12

    ASTM International is a member of CrossRef.

    Citation Format

    ASTM C1743-12, Standard Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential Building Construction, ASTM International, West Conshohocken, PA, 2012, www.astm.org

    Back to Top