    ASTM C1667 - 15

    Standard Test Method for Using Heat Flow Meter Apparatus to Measure the Center-of-Panel Thermal Transmission Properties of Vacuum Insulation Panels

    Active Standard ASTM C1667 | Developed by Subcommittee: C16.30

    Book of Standards Volume: 04.06

      Format Pages Price  
    PDF 9 $44.00   ADD TO CART
    Hardcopy (shipping and handling) 9 $44.00   ADD TO CART
    Standard + Redline PDF Bundle 18 $52.80   ADD TO CART

    Significance and Use

    5.1 Heat flow meter apparatus are being used to measure the center-of-panel portion of a vacuum insulation panel, which typically has a very high value of thermal resistivity (that is, equal to or greater than 90 m-K/W). As described in Specification C1484, the center-of-panel thermal resistivity is used, along with the panel geometry and barrier material thermal conductivity, to determine the effective thermal resistance of the evacuated panel.

    5.2 Using a heat flow meter apparatus to measure the thermal resistivity of non-homogenous and high thermal resistance specimens is a non-standard application of the equipment, and shall only be performed by qualified personnel with understanding of heat transfer and error propagation. Familiarity with the configuration of both the apparatus and the vacuum insulation panel is necessary.

    5.3 The center-of-panel thermal transmission properties of evacuated panels vary due to the composition of the materials of construction, mean temperature and temperature difference, and the prior history. The selection of representative values for the thermal transmission properties of an evacuated panel for a particular application must be based on a consideration of these factors and will not apply necessarily without modification to all service conditions.

    1. Scope

    1.1 This test method covers the measurement of steady-state thermal transmission through the center of a flat rectangular vacuum insulation panel using a heat flow meter apparatus.

    1.2 Total heat transfer through the non-homogenous geometry of a vacuum insulation panel requires the determination of several factors, as discussed in Specification C1484. One of those factors is the center-of-panel thermal resistivity. The center-of-panel thermal resistivity is an approximation of the thermal resistivity of the core evacuated region.

    1.3 This test method is based upon the technology of Test Method C518 but includes modifications for vacuum insulation panel applications as outlined in this test method.2

    1.4 This test method shall be used in conjunction with Practice C1045 and Practice C1058.

    1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    ASTM Standards

    C168 Terminology Relating to Thermal Insulation

    C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

    C740 Practice for Evacuated Reflective Insulation In Cryogenic Service

    C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions

    C1058 Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation

    C1484 Specification for Vacuum Insulation Panels

    E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods

    E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

    ICS Code

    ICS Number Code 91.060.10 (Walls. Partitions. Facades)

    UNSPSC Code

    UNSPSC Code 30161505(Panels or paneling); 41110000(Measuring and observing and testing instruments)

    Referencing This Standard

    DOI: 10.1520/C1667-15

    ASTM International is a member of CrossRef.

    Citation Format

    ASTM C1667-15, Standard Test Method for Using Heat Flow Meter Apparatus to Measure the Center-of-Panel Thermal Transmission Properties of Vacuum Insulation Panels, ASTM International, West Conshohocken, PA, 2015,