Significance and Use
The purpose of this practice is to simulate the aging process of cellulosic loose-fill insulation. By identifying any changes in flame retardant permanency due to the aging process, producers can design loose-fill insulation to meet or exceed material specifications throughout the product life cycle.
1. Scope
1.1 This practice covers a procedure to simulate the aging process of cellulosic loose-fill insulation by subjecting it to controlled laboratory conditions of temperature and humidity so that the insulation will be further evaluated, particularly for critical radiant flux characteristics.
1.2 It is not the intent of this practice to establish aging conditions that represent all possible exposures.
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
2. Referenced Documents (purchase separately)
The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C168 Terminology Relating to Thermal Insulation
C687 Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation
C739 Specification for Cellulosic Fiber Loose-Fill Thermal Insulation
C870 Practice for Conditioning of Thermal Insulating Materials
C1485 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source
E970 Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source
Other Document
NBSIR84-2917 Environmental Cycling of Cellulosic Thermal Insulation and Its Influence on Fire Performance
Index Terms
aging; cellulosic fiber loose-fill; conditioning; humidity/temperature cycling; thermal insulation; Humidity/temperature aging; Loose-fill thermal insulation; Simulated aging; Thermal insulating materials;
ICS Code
ICS Number Code 91.100.60 (Thermal and sound insulating materials)
DOI: 10.1520/C1488-04E01
ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]