Abstract
This specification covers either untextured or surface textured non-asbestos fiber-cement flat sheets intended for exterior applications such as claddings, facades, curtain walls, soffits, and so forth. This specification does not apply to asbestos-cement flat sheets, gypsum-based boards or particle boards, discrete non-asbestos fiber-cement interior substrate sheets, fiber-mat reinforced non-asbestos cement interior substrate sheets, or cement-bonded particleboards. Flat sheets covered here are divided into two types according to their intended application, and four grades according to their flexural strengths. Type A sheets are intended for exterior applications subjected to the direct action of sun, rain, or snow, while Type B sheets are intended for exterior applications not subjected to the direct action of sun, rain, or snow. Sheets shall adhere to the following mechanical and physical requirements: flexural strength, density, dimension (nominal length, width, and thickness, squareness, and edge straightness), finish, and color.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers either untextured or surface textured fiber-cement flat sheets intended for exterior applications such as claddings, facades, curtain walls, soffits, and so forth.
1.2 This specification is not applicable to asbestos-cement flat sheets (Specification C 220), gypsum-based boards (Specifications C 1396/C 1396M, C 1177/C 1177M, C 1178/C 1178M), or particle boards (Terminology D 1554) discrete non-asbestos fiber-cement interior substrate sheets (Specification C 1288), fiber-mat reinforced non-asbestos cement interior substrate sheets (Specification C 1325), or cement-bonded particleboards (Specification BS 5669: Part 4) and (ISO 8335).
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
2. Referenced Documents
British Standards
ASTM Standards
C1154 Terminology for Non-Asbestos Fiber-Reinforced Cement Products
C1177/C1177M Specification for Glass Mat Gypsum Substrate for Use as Sheathing
C1178/C1178M Specification for Coated Glass Mat Water-Resistant Gypsum Backing Panel
C1185 Test Methods for Sampling and Testing Non-Asbestos Fiber-Cement Flat Sheet, Roofing and Siding Shingles, and Clapboards
C1288 Specification for Discrete Non-Asbestos Fiber-Cement Interior Substrate Sheets
C1325 Specification for Non-Asbestos Fiber-Mat Reinforced Cementitious Backer Units
C1396/C1396M Specification for Gypsum Board
C220 Specification for Flat Asbestos-Cement Sheets
D1554 Terminology Relating to Wood-Base Fiber and Particle Panel Materials
E84 Test Method for Surface Burning Characteristics of Building Materials
International Standards
Index Terms
air cured; appearance; autoclaved cured; cellulose fiber; density; edge straightness; exterior application; finish; flexural strength; frost resistance; heat/rain resistance; inspection; length and width tolerance; mechanical properties; minimum equilibrium strength; minimum wet strength; moisture content; moisture movement; nominal length; nominal thickness; nominal width; non-asbestos fiber; packaging; physical properties; polyethylene fiber; polyvinyl alcohol fiber; pressure cured; rejection; sampling; sheet grading; shipping; squareness tolerance; storage; supplementary requirements; supplementary tests; surface burning characteristics; thickness requirements; thickness tolerance; third party certification; tolerance; Type A; Type B; type tests; warm water resistance; water absorption; water tightness; workmanship; Building facades; Building materials/applications--specifications; Ceiling suspension systems--specifications; Cellulose fiber--specifications; Cladding; Curtain walls; Edge straightness; Exterior building applications; Fiber-cement products--specifications; Flat asbestos sheet; Flooring/floor covering systems--specifications; Interior applications; Nonasbestos fiber-cement materials--specifications; Squareness tolerance; Partitions--specifications; Polypropylene (PP) fibers; Poly(vinyl acetate)(PVAC) fiber; Supplementary requirements; Sheet materials (general); Soffits; Thickness; Thickness tolerance; Tolerances; ICS Number Code 91.100.40 (Products in fibre-reinforced cement)