Significance and Use
The tests called for herein, for their results, indicate the acceptability of installed vitrified clay pipelines.
1. Scope
1.1 This test method defines procedures for hydrostatic infiltration testing of new installations of vitrified clay pipe lines, to demonstrate the structural integrity of the installed line. Refer to Practice C 12.
1.2 This test method is suitable for testing gravity-flow pipe lines constructed of vitrified clay pipe or combinations of clay pipe and other pipe materials.
1.3 This test method is applicable to the testing of the pipe lines only. Manholes or other structures should be tested separately.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately)
The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C12 Practice for Installing Vitrified Clay Pipe Lines
C828 Test Method for Low-Pressure Air Test of Vitrified Clay Pipe Lines
C896 Terminology Relating to Clay Products
Keywords
air test; clay pipe; hydrostatic test; infiltration; pipe; pressure test; sewers; vitrified clay pipe; water test; Acceptance criteria/testing--clay pipe/fittings; Clay pipe/piping systems; Exfiltration rate; Field testing; Hydrostatic testing; Infiltration rate; Pressure testing--clay pipe; Pressure testing--pipes; Sewerlines; Standpipes; Vitrified clay pipe/fittings; Water analysis; Water supply/distribution systems; Water test
ICS Code
ICS Number Code 91.100.25 (Terracotta building products)
DOI: 10.1520/C1091-03AR08
ASTM International is a member of CrossRef.
Citing ASTM Standards
[Back to Top]