ASTM B878 - 97(2009)

    Standard Test Method for Nanosecond Event Detection for Electrical Contacts and Connectors

    Active Standard ASTM B878 | Developed by Subcommittee: B02.11

    Book of Standards Volume: 02.04


    Buy Standard (PDF)
    4 pages
    $37.00
    Buy Standard (Print)
    4 pages
    $37.00
    Buy Standard + Redline (PDF)
    8 pages
    $44.40

    Historical (view previous versions of standard)


    ASTM B878

    Significance and Use

    The tests in this test method are designed to assess the resistance stability of electrical contacts or connections.

    The described procedures are for the detection of events that result from short duration, high-resistance fluctuations, or of voltage variations that may result in improper triggering of high speed digital circuits.

    In those procedures, the test currents are 100 mA (±20 mA) when the test sample has a resistance between 0 and 10 Ω. Since the minimum resistance change required to produce an event (defined in 3.2.1) is specified as 10 Ω (see 1.3), the voltage increase required to produce this event must be at least 1.0 V.

    The detection of nanosecond-duration events is considered necessary when an application is susceptible to noise. However, these procedures are not capable of determining the actual duration of the event detected.

    The integrity of nanosecond-duration signals can only be maintained with transmission lines; therefore, contacts in series are connected to a detector channel through coaxial cable. The detector will indicate when the resistance monitored exceeds the minimum event resistance for more than the specified duration.

    The test condition designation corresponding to a specific minimum event duration of 1, 10, or 50 ns is listed in Table 1. These shall be specified in the referencing document.

    TABLE 1 Test Condition Designations for Specific Minimum Event Durations

    Test ConditionEvent Duration, min
    A 1 nanosecond
    B10 nanoseconds
    C50 nanoseconds

    1. Scope

    1.1 This test method describes equipment and techniques for detecting contact resistance transients yielding resistances greater than a specified value and lasting for at least a specified minimum duration.

    1.2 The minimum durations specified in this standard are 1, 10, and 50 nanoseconds (ns).

    1.3 The minimum sample resistance required for an event detection in this standard is 10 Ω.

    1.4 An ASTM guide for measuring electrical contact transients of various durations is available as Guide B 854.

    1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

    1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to become familiar with all hazards including those identified in the appropriate Material Safety Data Sheet (MSDS) for this product/material as provided by the manufacturer, to establish appropriate safety and health practices, and determine the applicability of regulatory limitations prior to use.


    2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.

    Other Standards

    EN 50 082-1:94

    ASTM Standards

    B542 Terminology Relating to Electrical Contacts and Their Use

    B854 Guide for Measuring Electrical Contact Intermittences


    ICS Code

    ICS Number Code 17.220.20 (Measurement of electrical and magnetic quantities)

    UNSPSC Code

    UNSPSC Code 39121522(Electrical contacts); 39121461(Connector and cable seal)


    DOI: 10.1520/B0878-97R09