STP1519

    Measurement of Water Permeability of Roof Tiles and Influence of Entrapped Air

    Published: Jan 2010


      Format Pages Price  
    PDF (1.6M) 23 $25   ADD TO CART
    Complete Source PDF (25M) 23 $115   ADD TO CART


    Abstract

    Freezing damage in roof tiles is caused by a temperature drop in conjunction with a percent of saturation inside the tile. In order to understand the freezing-thawing process, it is necessary to know the moisture transport characteristics of a roof tile. In general, Japanese roof tiles have surface finishes. In this study, the water permeability of roof tiles with and without surface finishes was measured. The measured results showed that tiles with surface finishes had water resistances a few thousand-fold higher than tiles without surface finishes. Furthermore, it appears that the air entrapped within the tile has a significant influence on moisture transport in the tile. The influence of air was examined by numerical analysis, which demonstrated that an increase in the entrapped air pressure suppressed water infiltration.

    Keywords:

    roof tile, water permeability, entrapped air, saturation


    Author Information:

    Iba, Chiemi
    Researcher, Hokkaido Northern Regional Building Research Institute, Hokkaido,

    Hokoi, Shuichi
    Professor, Kyoto Univ.,


    Paper ID: STP49024S

    Committee/Subcommittee: C16.30

    DOI: 10.1520/STP49024S


    CrossRef ASTM International is a member of CrossRef.