STP148E

    D 1426 - 58 Standard Methods of Test for Ammonia in Industrial Water and Industrial Waste Water

    Published: Jan 1960


      Format Pages Price  
    PDF Version (200K) 6 $25   ADD TO CART
    Complete Source PDF (24M) 6 $152   ADD TO CART


    Abstract

    (a) These methods cover the determination of ammonia and ammonium ions present in industrial water and industrial waste water. Two methods are given, as follows: (b) The Referee Method is applicable to all types of industrial water, including industrial waste water, for the determination of ammonia concentrations usually encountered in such waters. The Non-Referee Method may be used for the rapid routine determination of ammonia in such waters. In both methods, all determinations should be carried out at room temperature (25 to 30 C).