STP145: Comparison of Non-Destructive Tests on A Damaged Sternpost

    De Sterke, A
    Roentgen Technische Dienst, Overschie,

    Den Hartog, H
    Roentgen Technische Dienst, Overschie,

    Pages: 10    Published: Jan 1953


    Abstract

    Comparative non-destructive and destructive tests on a damaged sternpost indicate how magnetic and ultrasonic inspection can be used to obtain a full picture of the location of surface and internal cracks. X-ray and gamma-ray inspection will provide additional information on the nature of the defects, especially in the thinner sections.


    Paper ID: STP39258S

    Committee/Subcommittee: E07.01

    DOI: 10.1520/STP39258S


    CrossRef ASTM International is a member of CrossRef.