Elevated Temperature Testing Methods

Source

Techniques of axial strain-controlled fatigue testing at elevated temperature are described. The specimen design incorporates thin ridges for attaching the extensometer arms; details of the design are provided to avoid premature failure at these discontinuities. Special problems of specimen gripping, alignment, and break detection at high temperature are discussed for both mechanical and closed-loop hydraulic testing machines.

Author Information

Wells, CH
ASTM, Middletown, Conn.
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: E08
Pages: 87–99