SYMPOSIA PAPER Published: 01 January 1974
STP33133S

Influence of Three-Dimensional Effects on the Stress Intensity Factors of Compact Tension Specimens

Source

The stress freezing technique of photoelasticity was utilized to study the stress intensity variation between full thickness and center slices of compact tension specimens for various crack lengths. Specimen geometries covered an a/w range of 0.3 to 0.7 for values of w/B of 2 and 3.5.

Normalized stress intensity factor results for geometries within ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-72) specifications (that is, w/B = 2.0, a/w = 0.50) agreed with the ASTM solution to within experimental error. However, for a/w values outside the ASTM range (0.45 to 0.55), experimental results were measurably higher than the ASTM results for w/B = 2.0 and averaged 13 percent higher for all a/w studied at w/B = 3.5. The center slice SIF was found to be 5 to 10 percent higher than the through the thickness average on all tests.

Author Information

Schroedl, MA
Virginia Polytechnic Institute and State University, Blacksburg, Va.
Smith, CW
Virginia Polytechnic Institute and State University, Blacksburg, Va.
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: E08
Pages: 69–80
DOI: 10.1520/STP33133S
ISBN-EB: 978-0-8031-4645-7