STP877

    Crack Shape Monitoring Using A-C Field Measurements

    Published: Jan 1985


      Format Pages Price  
    PDF Version (252K) 15 $25   ADD TO CART
    Complete Source PDF (4.5M) 15 $55   ADD TO CART


    Abstract

    A multi-central processing unit (CPU) computer network has been installed at University College London for fatigue tests and automatic inspection work. This system is described, together with a newly developed alternating-current field measurement inspection system for crack measurement, in use on some novel stress corrosion tests. The complete system makes it possible to conduct tests where the crack shape evolution can be monitored.

    Keywords:

    crack measurement, crack shape, fatigue crack growth, fatigue testing


    Author Information:

    Topp, DA
    Research assistant and professor of mechanical engineering, London Centre for Marine Technology, University College London, Torrington Place, London,

    Dover, WD
    Research assistant and professor of mechanical engineering, London Centre for Marine Technology, University College London, Torrington Place, London,


    Paper ID: STP32881S

    Committee/Subcommittee: E08.03

    DOI: 10.1520/STP32881S


    CrossRef ASTM International is a member of CrossRef.