SYMPOSIA PAPER Published: 01 January 1984
STP32673S

Capacitive Microphone Tuning of Ultrasonic/Thermosonic Bonders

Source

Scheduling ultrasonic bonders for optimum settings has long been a mystery. As device bond pads get smaller and silicon and gallium arsenide devices get thinner, ultrasonic energy control at the bond interface becomes very critical. The use of a capacitive microphone sound meter to measure the compressional sound waves at the lower tip of a bonding tool has helped to control these critical energy settings. The results of implementing this process on 25 thermosonic bonders has reduced the damage to microwave devices by 30% and decreased the wire bond assembly time 25%.

Author Information

Loofbourrow, WL
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Developed by Committee: F01
Pages: 472–484
DOI: 10.1520/STP32673S
ISBN-EB: 978-0-8031-4915-1
ISBN-13: 978-0-8031-0403-7