STP790

    Thermal Evaluation of One-Ply Sheet Roofing

    Published: Jan 1982


      Format Pages Price  
    PDF Version (112K) 10 $25   ADD TO CART
    Complete Source PDF (2.4M) 10 $55   ADD TO CART


    Abstract

    This paper presents some preliminary data on the thermal analysis of one-ply roofing sheets. The differential scanning calorimetry (DSC) data show that DSC techniques may be used to identify the type of plastic or elastomer used in one-ply roofing sheets. Products manufactured by different producers, and weathered and unexposed specimens have different shaped curves. Once a library of curves has been established, DSC testing may be used not only to identify materials and their producers, but to show aging characteristics and degree and nature of damages from general exposure and environmental influences.

    Keywords:

    roofing, performance, durability, building materials, calorimetry, polymeric sheets, single ply, plastomeric sheets, differential scanning calorimeter


    Author Information:

    Cash, CG
    Senior associateConsulting Engineers, Simpson Gumpertz & Heger Inc., Cambridge, Mass.


    Paper ID: STP32471S

    Committee/Subcommittee: D08.21

    DOI: 10.1520/STP32471S


    CrossRef ASTM International is a member of CrossRef.