STP1015

    Transient Absorption of Light Induced by Radiation

    Published: Jan 1988


      Format Pages Price  
    PDF (64K) 6 $25   ADD TO CART
    Complete Source PDF (14M) 6 $77   ADD TO CART


    Abstract

    We have measured two components in the radiation-induced absorption of 250-nm light in fused silica. For the first, the time constant is 48.3 ± 1.3 ns and the absorption coefficent is 6.68 ± 0.37 cm-1 per Mrad. For the second, the time constant is long compared to 3 μs, and the absorption coefficient is 1.65 ± 0.36 cm-1 per Mrad. The errors quoted are purely statistical.

    Keywords:

    electron irradiation, fused silica, radiation damage, transient absorption


    Author Information:

    Godwin, R
    Los Alamos National Laboratory, Los Alamos, New Mexico

    Harrison, FB
    Los Alamos National Laboratory, Los Alamos, New Mexico

    Larson, A
    Los Alamos National Laboratory, Los Alamos, New Mexico


    Paper ID: STP18792S

    Committee/Subcommittee: F01.11

    DOI: 10.1520/STP18792S