    A Comparison of Portable and Permanent Landfill Liner Leak Detection Systems

    Published: Jan 1999


      Format Pages Price  
    PDF Version (292K) 18 $25   ADD TO CART
    Complete Source PDF (8.9M) 18 $81   ADD TO CART


    Abstract

    Monitoring of the integrity of electrically non-conductive geomembrane liners installed at waste sites using electrical geophysical techniques has been carried out for a number of years using above-liner leak location surveys and, more recently, below-liner monitoring systems. We compare the theoretical response of both types of survey to a hole in a liner and then compare with measurements made in the field. The theoretical leak response indicates that above-liner surveys are sensitive to leaks over a greater area, though both responses result in comparable leak detectability. However, field data suggest that in practice, measurements made on a sparse grid below the liner have the greater sensitivity to certain leaks. This may be due to the differing leak geometries and background conditions present above and below the liner.

    The results indicate that a sparse below-liner monitoring grid, with its long-term monitoring capabilities, combined with above-liner surveys to pinpoint leaks accurately offer a successful approach to ensuring liner integrity throughout the lifetime of a lined waste site.

    Keywords:

    leak detection, geomembrane liners, landfill monitoring, geophysics


    Author Information:

    Taylor, SB
    Researcher and Senior Lecturer, School of Earth Sciences, University of Birmingham, Edgbaston, Birmingham

    White, CC
    Technical Director, Technos Ltd., Shrewsbury, Shropshire

    Barker, RD
    Researcher and Senior Lecturer, School of Earth Sciences, University of Birmingham, Edgbaston, Birmingham


    Paper ID: STP14220S

    Committee/Subcommittee: D18.23

    DOI: 10.1520/STP14220S


    CrossRef ASTM International is a member of CrossRef.