STP1001

    Intercomparison of Activity Measurements in Different Laboratories on a Set of Monitor Foils Irradiated in a Spallation Neutron Spectrum

    Published: Jan 1989


      Format Pages Price  
    PDF (120K) 6 $25   ADD TO CART
    Complete Source PDF (15M) 6 $156   ADD TO CART


    Abstract

    A set of monitor foils composed of Ti. Fe, Ni, Co, Au, and Nb was irradiated for three months at the LAMPF beam stop with a neutron fluence of approximately 2 . 1019 cm-2. The activities of a representative selection of these foils were determined in an inter-laboratory comparison. The participating laboratories (CESNEF, PTB, SCK/CEN, and EIR) used their established measuring procedures. The methods are described briefly; apparent differences in the results and possible reasons for them are discussed.

    Keywords:

    activity measurements, intercomparison, neutron activation, neutron fluence monitors, germanium detector calibration