Journal Published Online: 10 October 2014
Volume 43, Issue 3

A Study on CMOD-Based Compliance Calibration Functions for Clamped Single-Edge Tension Specimens

CODEN: JTEVAB

Abstract

The compliance calibration function for the clamped single-edge tension (SE(T)) specimen has not been reported in the literature. Based upon the inverse fitting of the three existing CMOD-based compliance equations, three CMOD-based compliance calibration equations are proposed for specimens with a crack length-to-width ratio 0.05 ≤ a/W ≤ 0.75. The fitting errors of the equations here employed are no greater than 1 %.

Author Information

Wang, Enyang
Individual Researcher, London, Ontario, CA
Pages: 5
Price: $25.00
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Stock #: JTE20130333
ISSN: 0090-3973
DOI: 10.1520/JTE20130333