Volume 31, Issue 5 (September 2003)

    Temperature Effect on Strain Measurement by Using Weldable Electrical Resistance Strain Gages

    (Received 9 July 2002; accepted 23 April 2003)

    CODEN: JTEOAD

      Format Pages Price  
    PDF 7 $25   ADD TO CART


    Abstract

    Thermal output from two different strain gage types was analyzed over a temperature range from 20–500°C. The influence of applied loads was also examined. The strain gages were attached to the specimens in three different configurations. Thermal output was efficiently compensated for using a quarter-bridge configuration. Relative large errors were found using half-bridge configurations. The obtained thermal output values, with and without application of load, are discussed.


    Author Information:

    Gomes, PTV
    Nuclear Technology Research Center-CDTN/CNEN,

    Maia, NS
    Nuclear Technology Research Center-CDTN/CNEN,

    Mansur, TR
    Nuclear Technology Research Center-CDTN/CNEN,

    Palma, ES
    Pontifical Catholic University of Minas Gerais-PUC Minas,


    Stock #: JTE12366J

    ISSN: 0090-3973

    DOI: 10.1520/JTE12366J

    ASTM International is a member of CrossRef.