Volume 27, Issue 4 (July 1999)

    A Low-Temperature Modification to the Charpy Impact Test, with an Example Study of the Fracture Toughness of Mg-12%Li between 4.2 to 77 K

    (Received 7 August 1998; accepted 12 April 1999)

    CODEN: JTEOAD

      Format Pages Price  
    PDF 3 $25   ADD TO CART


    Abstract

    A modification to the Charpy test for measuring impact fracture toughness has been developed that permits the specimen to be bathed in flowing liquid helium while mounted on the testing machine's anvil immediately prior to impact. This method permits samples to be tested at any temperature between 4.2 and 77 K, which extends the Charpy test to temperatures lower than those achievable by the conventional liquid bath immersion technique. A body-centered cubic Mg-12%Li single-phase alloy was tested by this new method and found to have anomalously high impact fracture toughness in the temperature range 4.2 to 77 K.


    Author Information:

    Russell, AM
    Iowa State University, Ames, IA

    Ostenson, JE
    Iowa State University, Ames, IA


    Stock #: JTE12228J

    ISSN: 0090-3973

    DOI: 10.1520/JTE12228J

    ASTM International is a member of CrossRef.

    Author
    Title A Low-Temperature Modification to the Charpy Impact Test, with an Example Study of the Fracture Toughness of Mg-12%Li between 4.2 to 77 K
    Symposium , 0000-00-00
    Committee E28