SEDL / Journals / Journal of Testing and Evaluation (JTE) / Citation Page


Volume 17, Issue 1 (January 1989)

ISSN: 1945-7553
Page Count: 12


Dynamic Young's Modulus Measurements in Metallic Materials: Results of an Interlaboratory Testing Program

Wolfenden, A
Texas A&M University, College Station,TX

Harmouche, MR
Texas A&M University, College Station,TX

Blessing, GV
Ultrasonics Standards Group, National Bureau of Standards, Gaithersburg,MD

Chen, YT
Corporate R&D, Stamford,CT

Terranova, P
Corporate R&D, Stamford,CT

Dayal, V
North Carolina A&T State University, Greensboro,NC

Kinra, VK
Texas A&M University, College Station,TX

Lemmens, JW
Elektronika N.V., Leuven,

Phillips, RR
St. Marys,PA

Smith, JS
Inco Alloys International, Inc., Huntington,WV

Mahmoodi, P
Corporate Research Laboratories/3M, 3M Center, St. Paul,MN

Wann, RJ
Corporate Research Laboratories/3M, 3M Center, St. Paul,MN

(Received 15 March 1987; accepted 15 July 1988)

Abstract

The results of a round-robin testing study are presented for measurements of dynamic Young's modulus in two nickel-based alloys. The Interlaboratory Testing Program involved six types of apparatus, six different organizations, and specimens from a well-documented source. All the techniques yielded values of dynamic Young's modulus that agreed within 1.6% of each other. For Inconel alloy 600 the dynamic modulus was 213.5 GPa with a standard deviation of 3.6 GPa; for Incoloy alloy 907 the corresponding values were 158.6 and 2.2 GPa, respectively. No significant effect of frequency over the range 780 Hz to 15 MHz was found.



Keywords:
elastic modulus, dynamic, Young's modulus, metals, interlaboratory, frequency dependence

Paper ID: JTE11527J
DOI: 10.1520/JTE11527J
ASTM International is a member of CrossRef.

Author Title Dynamic Young's Modulus Measurements in Metallic Materials: Results of an Interlaboratory Testing Program Symposium , 0000-00-00 Committee D02