A Biaxial Fatigue Machine for Elevated Temperature Testing

Brown, MW
Senior research fellow and professormembers of ASTM, Sheffield University, Sheffield,

Miller, KJ
Senior research fellow and professormembers of ASTM, Sheffield University, Sheffield,

Abstract

A biaxial fatigue rig has been developed to study failure under low cycle fatigue conditions. The tubular specimen can be subjected to axial load, torque, and internal pressure enabling a wide range of stress/strain states to be obtained under strain-controlled conditions. A four zone furnace has been developed for elevated temperature tests, while allowing strains to be measured from the gauge length.



Keywords:
cyclic loads, temperature control, extensometers, fatigue tests, elevated temperature, plastic deformation, strain measurement, temperature measurement, test specimens, triaxial tests

Paper ID: JTE11228J
DOI: 10.1520/JTE11228J
ASTM International is a member of CrossRef.

Author Title A Biaxial Fatigue Machine for Elevated Temperature Testing Symposium , 0000-00-00 Committee E08