Volume 12, Issue 5 (September 1984)

    Single Specimen Fracture Toughness Testing of Low Strength Steel Plate Using The Direct Current Electrical Potential Method

    CODEN: JTEOAD

      Format Pages Price  
    PDF 8 $25   ADD TO CART


    Abstract

    The direct current electrical potential method for monitoring of crack length during fracture toughness JIc testing of low strength steels using the crack resistance curve approach is described. The experimental precautions and data processing procedure required for its application are described and discussed. Experimental data obtained from side-grooved, Charpy geometry specimens manufactured from a boiler plate steel are presented.


    Author Information:

    Doig, P
    Research officer and assistant technical officer, Central Electricity Generating Board, South Eastern Region, Gravesend,

    Abbott, KR
    Research officer and assistant technical officer, Central Electricity Generating Board, South Eastern Region, Gravesend,


    Stock #: JTE10730J

    ISSN: 0090-3973

    DOI: 10.1520/JTE10730J

    ASTM International is a member of CrossRef.

    Author
    Title Single Specimen Fracture Toughness Testing of Low Strength Steel Plate Using The Direct Current Electrical Potential Method
    Symposium , 0000-00-00
    Committee E08