    Laboratory Tests of Window-Wall Interface Details to Evaluate the Risk of Condensation on Windows

    (Received 8 March 2010; accepted 17 December 2010)

    Published Online: 2011

    CODEN: JTEOAD

      Format Pages Price  
    PDF Version 14 $25   ADD TO CART


    Abstract

    The development of alternative details to manage water intrusion at the window-wall interface has produced a number of novel approaches to detailing the interface between the window and the adjacent wall assembly. Many of these approaches advocate the need to provide drainage at the rough opening of the window subsill, given that the window components themselves are susceptible to water entry over their expected life. Depending on the types of windows used and the cladding into which the windows are installed, there arise different methods to provide drainage that may also affect air leakage through the assembly. This in turn may give rise to the formation of condensation along the window, at the sill, or along the window sash and glazing panels. Hence, there is a need to determine if, under cold weather conditions, specific interface details that incorporate sill pans provide a potential for condensation on the window components in which air leakage paths may be prominent at the sill or elsewhere on the window assembly. The paper reports on a laboratory evaluation of conditions suitable for the formation of condensation at the window frame perimeter of the interface assembly as a function of both temperature deferential and air leakage rate across the test assembly. A summary of the laboratory test protocol is provided, which includes a description of the test setup and apparatus, fabrication details of the specimen, information on instrumentation and calibration, and experimental results for one type of window (flange window). In parallel, preliminary simulation results were presented and compared to those obtained from the experiment using the commercially available thermal software BISCO.


    Author Information:

    Maref, Wahid
    Institute for Research in Construction, Ottawa, ON

    Van De Bossche, Nathan
    Ghent Univ., Jozef Plateaustraat, 22,

    Armstrong, Marianne
    Institute for Research in Construction, Ottawa, ON

    Lacasse, Michael A.
    Institute for Research in Construction, Ottawa, ON

    Elmahdy, Hakim
    Institute for Research in Construction, Ottawa, ON

    Glazer, Rock
    Institute for Research in Construction, Ottawa, ON


    Stock #: JTE103071

    ISSN: 0090-3973

    DOI: 10.1520/JTE103071

    ASTM International is a member of CrossRef.

    Author
    Title Laboratory Tests of Window-Wall Interface Details to Evaluate the Risk of Condensation on Windows
    Symposium Symposium on Condensation in Exterior Building Wall Systems, 2010-10-11
    Committee E06