ISSN: 0090-3973
Page Count: 12
Dynamic Young's Modulus Measurements in Metallic Materials: Results of an Interlaboratory Testing Program
Wolfenden, A
Texas A&M University,
TX
Harmouche, MR
Ultrasonics Standards Group, National Bureau of Standards,
MD
Blessing, GV
Corporate R&D,
CT
Chen, YT
North Carolina A&T State University,
NC
Terranova, P
Texas A&M University,
TX
Dayal, V
Elektronika N.V.,
Kinra, VK
PA
Lemmens, JW
Inco Alloys International, Inc.,
WV
Phillips, RR
Corporate Research Laboratories/3M, 3M Center,
MN
Smith, JS
Mahmoodi, P
Wann, RJ
Abstract
The results of a round-robin testing study are presented for measurements of dynamic Young's modulus in two nickel-based alloys. The Interlaboratory Testing Program involved six types of apparatus, six different organizations, and specimens from a well-documented source. All the techniques yielded values of dynamic Young's modulus that agreed within 1.6% of each other. For Inconel alloy 600 the dynamic modulus was 213.5 GPa with a standard deviation of 3.6 GPa; for Incoloy alloy 907 the corresponding values were 158.6 and 2.2 GPa, respectively. No significant effect of frequency over the range 780 Hz to 15 MHz was found.
Keywords:
elastic modulus, dynamic, Young's modulus, metals, interlaboratory, frequency dependence
Paper ID: JTE11527J
DOI: 10.1520/JTE11527J