ISSN: 0090-3973
Page Count: 4
Monitoring of Oxide Layer Thickness on Zircaloy-2 by the Eddy Current Test Method
Sinha, AK
Scientific Officer,
Bhabha Atomic Research Centre,
Shah, BK
Scientific Officer,
Bhabha Atomic Research Centre,
Kulkarni, PG
Head,
Bhabha Atomic Research Centre,
Abstract
To ensure adequate wear resistance on some of the nuclear reactor components made of Zircaloy-2, a uniform thick buff oxide layer is desirable. Commonly used methods to evaluate oxide thickness (i.e., metallography and weight gain) have certain limitations. In this paper, results of eddy current (ECT) monitoring as a function of oxide layer thickness (determined metallographically) on Zircaloy-2 surface have been reported. A linear correlation between ECT response and oxide layer thickness has been established.
Keywords:
eddy current test, nondestructive test method, oxide layer, Zircaloy-2
Paper ID: JTE11030J
DOI: 10.1520/JTE11030J
ASTM International is a member of CrossRef.
Author
Title Monitoring of Oxide Layer Thickness on Zircaloy-2 by the Eddy Current Test Method
Symposium , 0000-00-00
Committee B10