ISSN: 0090-3973
Page Count: 6
An Evaluation of a Load-Line Extensometer for Elastic-Plastic Fracture Toughness Testing
Williams, JA
Senior research engineer and advanced engineer,
W/A-124, Westinghouse Hanford Co.,
Wash.
Carlson, KW
Abstract
A load-line extensometer using linear variable differential transformer (LVDT) displacement transducers was developed and evaluated for use in multispecimen and single specimen J value versus crack growth (J-R) curve testing. The LVDT extensometer accuracy and repeatability was compared with that of clip gage extensometers commonly used in fracture toughness evaluatons. Data on load versus displacement and J value versus crack growth for ASTM A533, Grade B, Class 1 (Unified Numbering System [UNS] K12539) steel obtained by using both extensometers were also compared.
Keywords:
extensometers, fracture tests, crack propagation, unloading compliance tests, J integral, computer data acquisition
Paper ID: JTE11235J
DOI: 10.1520/JTE11235J
ASTM International is a member of CrossRef.
Author
Title An Evaluation of a Load-Line Extensometer for Elastic-Plastic Fracture Toughness Testing
Symposium , 0000-00-00
Committee E08