ISSN: 0090-3973
Page Count: 11
Life Expectancy for Fossil Steam Turbine Casings after 1000 000 Hours
Coulon, PA
Research engineer,
Alsthom-Atlantique, Steam Turbine Research Dept.,
Saisse, H
Metallurgist/engineer,
Marcoussis Laboratory, Route de Nozay,
Thauvin, G
Metallurgist/engineer,
Metallurgical Studies and Research Center, C.E.R.M., Alsthom-Atlantique,
Abstract
Today with the rapid development of nuclear electricity generation on a large scale, there arises the problem of maintaining fossil fuel generating stations that have been in operation for some 100 000 h or more. Operators usually hope to prolong the service life of units where safety margins permit, with objectives attaining beyond 150 000 h. This is an extremely ambitious program that is thwarted by the very nature of the work demanded from this type of thermal generating station: namely fulfillment of the needs of daily and seasonal peak periods, which increase the number of severe thermal operating transients.
This paper examines the question of metallurgical studies carried out by Alsthom-Atlantique on stator steel castings with a view to estimating their expectation of life potential. This work constitutes the second part of a study entitled “Quenching, Tempering, and Aging of Chromium-Molybdenum-Vanadium Cast Steels” in the Journal of Evaluation and Testing, Vol. 9, No. 2, March 1981.
Keywords:
steel castings, aging (metallurgy), embrittlement, steam turbine casings, service life, toughness, crack propagation, critical defect
Paper ID: JTE11582J
DOI: 10.1520/JTE11582J
ASTM International is a member of CrossRef.
Author
Title Life Expectancy for Fossil Steam Turbine Casings after 1000 000 Hours
Symposium , 0000-00-00
Committee F34